- 3 -
(3) Fatal Alarm
Table 1.3 (1/2)
ALARM
CATEGORY
ALARM
MAIN
CONTROL
ALARM
MPU internal
RAM alarm
Program
ROM alarm
RAM on
Control Board
alarm
EEPROM
alarm
WDT (Watch
Dog Timeout)
alarm
NMI signal
alarm
BRK instruction
alarm
MPU internal
RAM alarm
RAM on I/F
board alarm
I/F not
mounted
ROM alarm
Read/write error
Check sum error
Read/write error
No reaction when MPU
reads data
MPU is locked up and it is 
reset after 65 ms.
NMI port of MPU is kept
low level.
FFFF data is detected
due to MPU locked up.
Read/write error
Read/write error
No reaction from serial I/F
Board
: LED Blink (200 ms ON, 200ms OFF)
: LED Lights up.
Check sum error
Replace Power & Control Board
Replace ROM or Power & Control 
Board
Replace Power & Control Board
Replace Power & Control Board
Turn the power OFF and ON or
replace Power & Control Board
Replace Power & Control Board
Replace ROM or Power & Control 
Board
Replace I/F Board
Replace I/F Board
Replace I/F board or Power & Control 
Board
Replace ROM on I/F Board or 
I/F Board
FIRMWARE
DETECTION
ALARM
SERIAL
INTERFACE
ALARM
LED DISPLAY
REMARKS TROUBLESHOOTING
ALARM 10 12 15 17 20 PROP HSD UTL NLQ